Viola Tennessee
  • Sunday at 1:26 PM
  • #1

First attempt at solar. Here is a few pics of my EG4 Solar BrightMount ground mount work. Trench, anchored sonotubes, 2 cubic yards of 5k psi concrete, epoxy the bolts and mount the frames. Will square them up, run my 6 awg grounding hardware and drive the grounding rods into the ground. Suggestions welcome.

Attachments

  • 20240512_182354.jpg

    175.5 KB· Views: 42

  • sonotubes4.jpg

    183.5 KB· Views: 38

  • 20240526_183941.jpg

    280.8 KB· Views: 43

  • 33.jpg

    628.6 KB· Views: 41

cs1234

Solar Wizard
Joined
May 9, 2022
Messages
2,491
  • Sunday at 1:29 PM
  • #2

Kidvic said:

First attempt at solar. Here is a few pics of my EG4 Solar BrightMount ground mount work. Trench, anchored sonotubes, 2 cubic yards of 5k psi concrete, epoxy the bolts and mount the frames. Will square them up, run my 6 awg grounding hardware and drive the grounding rods into the ground. Suggestions welcome.

How far from your array to your existing building ground? The ground rods might not be needed for your situation.

Kidvic

New Member
Joined
Feb 20, 2021
Messages
16
Location
Viola Tennessee
  • Sunday at 1:48 PM
  • #3

cs1234 said:

How far from your array to your existing building ground? The ground rods might not be needed for your situation.

I actually don't know the answer SW. I'm erring on the side of caution. Pulled the rods for an old electric fence so I thought I'd use them. The distance from the grounding rods to my solar room is about 70 feet. I plan on driving an extra one just outside the room. Your thoughts are appreciated though ... thx

cs1234

Solar Wizard
Joined
May 9, 2022
Messages
2,491
  • Sunday at 1:54 PM
  • #4

Kidvic said:

I actually don't know the answer SW. I'm erring on the side of caution. Pulled the rods for an old electric fence so I thought I'd use them. The distance from the grounding rods to my solar room is about 70 feet. I plan on driving an extra one just outside the room. Your thoughts are appreciated though ... thx

It's generally recommended to not have any auxiliary ground rods on your system. You just need to make sure your panels/racking equipment/enclosures and such are all grounded back to the main building ground.. assuming that the solar system will be connected into that same buildings system. You just run that ground cable along with your PV + and PV - wires.

seneysolar

Solar Addict
Joined
Dec 17, 2023
Messages
856
Location
Michigan
  • Sunday at 1:59 PM
  • #5

Kidvic said:

First attempt at solar. Here is a few pics of my EG4 Solar BrightMount ground mount work. Trench, anchored sonotubes, 2 cubic yards of 5k psi concrete, epoxy the bolts and mount the frames. Will square them up, run my 6 awg grounding hardware and drive the grounding rods into the ground. Suggestions welcome.

Looks great! First attempt looks like a pro

L

Loadtoad

New Member
Joined
Mar 17, 2020
Messages
161
  • Sunday at 2:03 PM
  • #6

Why have all that disturbed soil from the trench all around the sontubes? Why not just use an attachment that digs the round holes the size of the tubes? It's definitely not going anywhere, but?

Kidvic

New Member
Joined
Feb 20, 2021
Messages
16
Location
Viola Tennessee
  • Sunday at 2:19 PM
  • #7

cs1234 said:

How far from your array to your existing building ground? The ground rods might not be needed for your situation.


Loadtoad said:

Why have all that disturbed soil from the trench all around the sontubes? Why not just use an attachment that digs the round holes the size of the tubes? It's definitely not going anywhere, but?

I thought the same. I bought an 18" auger for my tractor. The hole needed to be a little less than 4' deep. After 2 broken shear pins and a hole that slanted about 15 degrees I realized this wasn't going to work out as planned. I'm to old to be using post hole diggers for very long. Good question though ...

Philip53

10.4kw DIY Home Solar Sprinter Van DIY Victron
Joined
Aug 22, 2022
Messages
105
  • Sunday at 2:19 PM
  • #8

I am guessing all of those tubes bottom terminate into a full length concrete beam.

Great job!

Kidvic

New Member
Joined
Feb 20, 2021
Messages
16
Location
Viola Tennessee
  • Sunday at 2:20 PM
  • #9

seneysolar said:

Looks great! First attempt looks like a pro

Thanks bro ... need all the encouragement I can get : )

Kidvic

New Member
Joined
Feb 20, 2021
Messages
16
Location
Viola Tennessee
  • Sunday at 2:23 PM
  • #10

Philip53 said:

I am guessing all of those tubes bottom terminate into a full length concrete beam.

Great job!

I did have a little concrete left over so I just buttered the bottom with the remaining mix. Stabilized them somewhat...

Bluedog225

Texas
Joined
Nov 18, 2019
Messages
3,159
  • Sunday at 2:53 PM
  • #11

Looks great.

Subdood

Photon Wrangler
Joined
Mar 27, 2022
Messages
637
Location
NE Kentucky
  • Sunday at 3:08 PM
  • #12

Look good. What kind and how many panels will you be installing on the mount? Did you hand mix the concrete or did you have it brought in? I mixed about 20 50lb bags of Quikrete for 10 holes for my install.

Bluedog225

Texas
Joined
Nov 18, 2019
Messages
3,159
  • Sunday at 3:09 PM
  • #13

I’d be tempted to join those rails together to get a few more panels.

Kidvic

New Member
Joined
Feb 20, 2021
Messages
16
Location
Viola Tennessee
  • Sunday at 3:12 PM
  • #14

cs1234 said:

It's generally recommended to not have any auxiliary ground rods on your system. You just need to make sure your panels/racking equipment/enclosures and such are all grounded back to the main building ground.. assuming that the solar system will be connected into that same buildings system. You just run that ground cable along with your PV + and PV - wires.

Understood. Thx. Can I use solid 6 awg along with the PV wiring or should I do something like 6 awg THHN stranded wire? Your comments are appreciated. All new endeavor for me : ) An after thought .... would it be ok to use solid copper for ganging the panels together and use stranded AWG from the combiner box to the solar charge controller?

Last edited:

Kidvic

New Member
Joined
Feb 20, 2021
Messages
16
Location
Viola Tennessee
  • Sunday at 3:15 PM
  • #15

Bluedog225 said:

I’d be tempted to join those rails together to get a few more panels.

I have mixed thoughts on that. Being a newbie I don't know the answer. It almost seems like it would be easier to adjust the panels and frame if they were smaller. If they were all connected I'd have to have a half a dozen helpers to change the angle of all of them put together. I may not be seeing the entire picture though ... appreciate your input. Thx

Bluedog225

Texas
Joined
Nov 18, 2019
Messages
3,159
  • Sunday at 3:17 PM
  • #16

Kidvic said:

I have mixed thoughts on that. Being a newbie I don't know the answer. It almost seems like it would be easier to adjust the panels and frame if they were smaller. If they were all connected I'd have to have a half a dozen helpers to change the angle of all of them put together. I may not be seeing the entire picture though ... appreciate your input. Thx

True that. I didn’t notice they were adjustable.

Bluedog225

Texas
Joined
Nov 18, 2019
Messages
3,159
  • Sunday at 3:18 PM
  • #17

I was told recently by one of our resident experts that stranded insulated was his preference for grounding conductor.

Kidvic

New Member
Joined
Feb 20, 2021
Messages
16
Location
Viola Tennessee
  • Sunday at 3:25 PM
  • #18

Subdood said:

Look good. What kind and how many panels will you be installing on the mount? Did you hand mix the concrete or did you have it brought in? I mixed about 20 50lb bags of Quikrete for 10 holes for my install.

I opted for the REC Solar REC420AA-PURE-R Alpha Series 420 watt panels. A Norwegian company that had good reviews. I bought a few bags of concrete from Lowes but after calculating the amount of mix I'd need I changed my mind. Too old : ) Having the concrete delivered wasn't that much more expensive than buying individual bags and mixing it myself. I had them mix it thin with chips which will make it tight and strong. I wound up using 2 cubic yards for the (12) 12" x 4' sonotubes. Having done it once I feel more confident doing it again if I chose to expand my array. My biggest mistake was allowing a rain storm to fill my trench with about 8" of water. Had to hand bail with a bucket. ugh

Kidvic

New Member
Joined
Feb 20, 2021
Messages
16
Location
Viola Tennessee
  • Sunday at 3:26 PM
  • #19

Kidvic

New Member
Joined
Feb 20, 2021
Messages
16
Location
Viola Tennessee
  • Sunday at 3:28 PM
  • #20

Bluedog225 said:

I was told recently by one of our resident experts that stranded insulated was his preference for grounding conductor.

Yes ... I kind of figured that would be the answer. Always the more expen$ive option : ) Thx

You must log in or register to reply here.

Sonotubes for my solar array ... (2024)
Top Articles
Latest Posts
Article information

Author: Catherine Tremblay

Last Updated:

Views: 5573

Rating: 4.7 / 5 (47 voted)

Reviews: 94% of readers found this page helpful

Author information

Name: Catherine Tremblay

Birthday: 1999-09-23

Address: Suite 461 73643 Sherril Loaf, Dickinsonland, AZ 47941-2379

Phone: +2678139151039

Job: International Administration Supervisor

Hobby: Dowsing, Snowboarding, Rowing, Beekeeping, Calligraphy, Shooting, Air sports

Introduction: My name is Catherine Tremblay, I am a precious, perfect, tasty, enthusiastic, inexpensive, vast, kind person who loves writing and wants to share my knowledge and understanding with you.